Skip to content
Vandiver Heating & Air
A UV lamp mounted through an access panel with a clear line of sight to the evaporator coil.

Indoor Air Quality

UV Coil Treatment in Woodstock, GA

A UV lamp aimed at the evaporator coil keeps biological growth off the wet surface inside your air handler. It is a small, quiet piece of equipment whose entire job is to keep the coil from becoming the thing that makes your house smell like a basement.

We fit them during tune-ups and installs, and we are deliberately narrow about what we claim for them.

What it does

  • Keeps the evaporator coil and drain pan clear of biological growth
  • Addresses the musty smell that appears when the system first starts
  • Keeps a coil that has been cleaned from re-fouling as quickly
  • Runs continuously and silently, with no effect on airflow

Who it's for

  • Houses with a recurring musty smell at start-up
  • Systems where the coil has been cleaned once already
  • Homes with high indoor humidity and a coil that stays wet
  • Anyone having an air handler replaced, when the lamp can be sited properly at install

What's included

  • Lamp mounted with a real line of sight to the coil surface, which is the whole mechanism
  • Access panel cut and gasketed so the lamp can be changed without a service call
  • Power taken from the air handler properly, with a service switch
  • Lamp replacement date written on the cabinet, because output falls long before the lamp goes dark

Usually added during a tune-up or an install

Questions people ask before booking

  • Does it need maintenance?

    The lamp is an annual or biennial replacement depending on the type. Output falls well before the lamp stops glowing, so a lamp that still looks lit is not evidence it is still working. We date the cabinet.

  • Can it be added during another visit?

    Yes, and an install or a coil cleaning is the right moment — the panel is already off and the coil is at its cleanest, which is the condition the lamp is good at maintaining.

  • What does it not do?

    It is a coil treatment. It is not an air-sterilization system, it does not treat the air passing through in the fraction of a second it is in front of the lamp, and we are not going to tell you otherwise. If your goal is particulate and allergens, that is a filtration conversation, not a UV one.

Available across 10 towns in Cherokee County and the north metro. See where we work.

Book this service

  1. 1. What's going on
  2. 2. Where
  3. 3. You
What is happening, and how urgent it is
What's going on? (required)
Which system? (required)
Is this an emergency? (required)
Call (770) 555-0187Book a service call